InternationalFX and VFX Series INVERTER/CHARGER Programming Manual

Strona 2 - WARRANTY SUMMARY

9ADVANCED SCREENSAll the FX operation settings can be adjusted in the MATE’s ADVANCED screens, including some previously discussed in the INPUT and SE

Strona 3 - TABLE OF CONTENTS

10ADVchoose device:FX CC DC MATEADV/FX/PAGE 1-----------------choose category:ADV INV CHGR PG2ADV/FX/INVERTER-------

Strona 4 - DECLARATION OF CONFORMITY

11ADV/FX/INVERTER-------P00search 60 cyclespulse spacingDOWN INC DEC PORTADV/FX/INVERTER-------P00low battery

Strona 5 - KEEP THESE INSTRUCTIONS

12ADV/FX/INVERTER-------------reset FX to factorydefaultsDOWN MORETo reset to factory defaults, press if

Strona 6 - FX MODES AND PROPERTIES

13ADVchoose device:FX CC DC MATEADV/FX/PAGE 1-----------------choose category:ADV INV CHGR PG2ADV/FX/CHARGER--------

Strona 7

14ADV/FX/CHARGER---------P00absorb 01.0 hrstime limitDOWN INC DEC PORTADV/FX/CHARGER---------P00 oat

Strona 8

15ADV/FX/CHARGER---------P00equalize 14.6 vdcset pointDOWN INC DEC PORTADV/FX/CHARGER---------P00equalize

Strona 9

16GENERATOR MENUOutBack FX and VFX Inverter/Chargers are programmed to use an AC generator as their default source of AC input. The CHARGER GEN scree

Strona 10 - ADVANCED SCREENS

17ADV/FX/GEN---------------P00ac2/gen 208 vaclower limitDOWN INC DEC PORTADV/FX/GEN---------------P00ac2/gen

Strona 11 - INVERTER MENU

18ADV/FX/GEN---------------P00ac2/gen OFFsupportDOWN OFF ON PORT ADV/FX/GEN-----------------

Strona 12

1WARRANTY SUMMARYDear OutBack Customer,Thank you for your purchase of OutBack products. We make every e ort to assure our power conversion products w

Strona 13 - ADV/FX/INVERTER

19FX SERIES INVERTER/CHARGER PROGRAMMINGNOTE: Please see the International FX and VFX Series Inverter/Charger Installation Manual to install, wire, an

Strona 14 - CHARGER MENU

20The FX connected to Port 01 is always programmed as the MasterAC Breakers O DC Breakers O COMPONENTS AND CONNECTIONS:1. With all AC and DC break

Strona 15

21AC Breakers O DC Breakers On2. With the FXs connected to the HUB, turn only the DC breakers ON and power up the components. All AC breakers should

Strona 16

223. After powering up the components, connect the MATE to the HUB. PATH MAIN--------------------- SETUP------------------ SETUP/MATE/PAGE1 SET

Strona 17 - GENERATOR MENU

23STACKING OPTIONSOutBack International Series FXs can be stacked in one of two con gurations:1. OutBack Parallel 2. 3-PhaseNOTE: Although stacking

Strona 18

242. 3-Phase• Three—and only three— FXs are connected, one to each of three 230 VAC output legs that produce 400 VAC between any two legs of the syst

Strona 19 -

252. Classic Slave• Classic Slave is the designation of the second FX in a two-inverter, split-phase system that produces 400VAC without using an FW-

Strona 20 - Stacking Options

26 Once the MATE recognizes each FX (and OutBack Charge Controller), push and hold the  rst two soft keys simultaneously to return to the MA

Strona 21 - COMPONENTS AND CONNECTIONS:

27ADVchoose device:FX CC DC MATEADV/FX/PAGE 1-----------------choose category:ADV INV CHGR PG2On the ADV/FX/PAGE 1 sc

Strona 22 - DC Breakers On

28ADV/FX/STACK--------P01stack 1-2ph MasterphaseDOWN INC DEC PORTStacking the FX Series Inverter/Chargers begins on thi

Strona 23 - MATE Screens

2TABLE OF CONTENTSWarranty Summary...

Strona 24 - STACKING OPTIONS

2912PH MASTERWith the Port 01 FX as the Master, press the <PORT> soft key to change the remaining Ports and designate the remaining FXs as Slav

Strona 25 - 1. 1-2ph Master

30ADV/FX/STACK----------P02stack OB Slave L1phaseDOWN INC DEC PORTOUTBACK OB SLAVE L2• Set the FXs you want as

Strona 26 - 5. 3ph Slave

31ADV/FX/STACK----------P01stack 3ph MasterphaseDOWN INC DEC PORT3PHASE 3PH SLAVE• Set the two Slave FXs t

Strona 27 - 141

32INTRODUCTION TO POWER SAVE LEVELS Depending on the model, each FX consumes 20-25 watts of power when it remains on, even if it isn’t actively invert

Strona 28

33The default value for the power save level slave adjust only screen is 1. Press the <INC> or <DEC> soft keys to adjust this value. Press

Strona 29 - DOWN INC DEC PORT

34BYPASS OUTPUT INPUTWith the programming completed, turn the AC output breakers ON with the AC BYPASS on the AC breaker panel switched to NORMAL.Veri

Strona 30 - OUTBACK OB SLAVE

35If the FX’s AC source is available, the yellow AC IN STATUS light will blink. The FX will connect to the utility grid when the voltage is within 200

Strona 31 - 3PHASE 3PH MASTER

36PRESS <INC> UNTIL 141, THEN PRESS ENTER.STACKING SYSTEM EXAMPLES OutBack Parallel Stacking• Four FXs in a single system are referred to as a

Strona 32 - 3PHASE 3PH SLAVE

37RANKING THE SLAVESStart from the last ADV/FX/STACK screen.Press the <PORT> soft key until P02 is displayed. This menu pertains to the Slaves

Strona 33 - DOWN INC DEC PORT

38After setting up your OutBack Parallel Stacking and establishing the Master and Slave order, shut o all the AC input and output breakers and check

Strona 34 - ADV/FX/STACK

3DECLARATION OF CONFORMITYThe OutBack Power Systems FX Series Inverter/Chargers export (“E”) models comply with the EU Declaration of Conformity regar

Strona 35 - POWERING UP

393-Phase Stacking (Three FX Series Inverter/Chargers Only)A 3-phase stacked system with only three FXs must be set up as described here:• Turn o al

Strona 36 - BYPASS OUTPUT INTPUT

40 ADV/FX/STACK--------P02stack 1-2ph MasterphaseDOWN INC DEC PORTADV/FX/STACK---------P03stack 3ph Slavephase DOW

Strona 37 - STACKING SYSTEM EXAMPLES

41The screen displays <132>. Press the <INC> soft key until it scrolls to the password 141.ADV/PASSWORDenter the password

Strona 38 - RANKING THE SLAVES

42ADV/FX/PG2---------------------choose category:PG1 GRID GEN PG3Press the <PG3> soft key which leads tothe ADV/FX/PAGE3 screen.A

Strona 39

43LIST OF AUX FUNCTIONS• Cool Fan activates the standard TurboFan which cools the FX during an over temperature condition.• Divert DC and Divert AC al

Strona 40 - PRESS INC FOUR TIMES

44ADV/FX/AUX-------------P00aux output RemotefunctionDOWN INC DEC PORT From the Remote aux output function scre

Strona 41 - PRESS DOWN THREE TIMES

45ADV/FX/AUX--------------P00genalert 9 mino delayDOWN INC DEC PORT After a battery has recharged o

Strona 42

46BATTERY CHARGING Keeping your battery bank energized is very important. Although a battery bank can last for many years if properly cared for, it c

Strona 43

47BATTERY CHARGING INSTRUCTIONSBattery Charging Set PointsRecharging set points are programmed using the OutBack MATE in the ADV/FX/CHARGER screens. T

Strona 44 - LIST OF AUX FUNCTIONS

48Battery Charging Sequence1. BULK • FX uses as much AC current as possible to raise the battery voltage to ABSORB (time period for BULK charging va

Strona 45

4WELCOME TO THE OUTBACK POWER SYSTEMS FX SERIESINVERTER/CHARGER SYSTEMThe FX and VFX Series Inverter/Charger o ers a complete power conversion system

Strona 46

49• External DUMP LOAD is Limiting Battery Voltage: Wind turbines and micro-hydro systems can produce very high voltages depending on wind and water

Strona 47 - MAINTENANCE

5012 VDC System DEFAULT MINIMUM MAXIMUMFloat Voltage 13.6V 12V 15VAbsorb Voltage 14.4V 13V 16VEQ Voltage 14.4V 14V 17VReFloat 12.5V 11V 13VLBCO 10.5V

Strona 48 - BATTERY CHARGING INSTRUCTIONS

51TWO YEAR LIMITED WARRANTY INFORMATIONFX Series Inverter/Charger ProductsOutBack Power Systems, Inc. (“OutBack”) provides a two year (2) limited warr

Strona 49 - Battery Charging Sequence

52Revision.2008-04-01To request warranty service, you must contact OutBack Technical Services at 360.435.6030 (North America), +34.93.654.9568 (Europ

Strona 50

53 LIMITED WARRANTY REGISTRATION Complete this form to request a Limited Warranty, and return it to: Outback Power Systems Inc.

Strona 52

55www.outbackpower.com900-0084-01-00 REV CCorporate Headquarters19009 62nd Avenue NEArlington, WA 98223 USAPhone: (+1) 360.435.6030 European Sales O

Strona 53

5FX MODES AND PROPERTIESEach OutBack FX and VFX comes with various default values set at the factory. Typically, a single FX in-stallation will retain

Strona 54 - REGISTRATION

6 Use the search sensitivity screen to determine the size of an AC load needed for the FX to turn ON and leave SEARCH mode. • Pressing

Strona 55

7 Pressing returns you to the SETUP/FX/SEARCH screen. Pressing returns the user to the choose category screen. Pressing

Strona 56 - 900-0084-01-00 REV C

8 To choose your AC input source in the ac transfer control screen, press or . Press to view the next screen.